Accumax Electro Magnetic Flow Meter
Line/Pipe Size
- 15
- 20
- 25
- 40
- 50
- 65
- 80
- 100
- 125
- 150
- 200
- 250
- 300
Lining Material
- PTFE
- PFA
- Rubber
Electrode Material
- SS316L
- Hastelloy ‘C’
Flange & Coil Housing
- MS
- SS
Class of Flange
- 150
- 300
- 600
Special Paint
- Siemens Grey
- Custom
Output 4 to 20mA
- No - 0
- Yes - 1
Output R485 (Modbus)
- No - 0
- Yes - 1
Display
- Integrated(I)
- Remote(R)
Pulse Output
- No - 0
- Yes - 1
Supply Voltage
- 220V AC
- 110V AC
- 24V DC
Aux Display
- Wire
- Wireless
The meter is true volume measuring meter. The measurement is independent of viscosity, Density, Dissolved/Undissolved solids, pressure or temperature of the flowing liquid as long as it maintains certain minimum conductivity. Various types of Liners & Electrodes are used as per application requirements. Empty pipe detection is also provided.
Features
Bridgetech Innovations Single Jet Water Meters are manufactured using high quality materials and with top notch precision to give accurate readings and reliability for a long time.
Robust & Rugged
Due to IP67-rated rugged construction our meters are Flameproof (IS/IEC 60079-1:2007) & Weatherproof. These can function in Potentially Explosive Atmosphere (IS/IEC 60079-0: 2004).
No Pressure Drop
With Accumax Electromagnetic Meters enjoy uninterrupted water flow with our full-bore construction. This eliminates pressure loss, ensuring optimal water delivery.
Maintenance Free
These meters are designed with no moving parts, eliminating the need for regular maintenance. Non-invasive measurement techniques guarantee excellent dependability
Long Lasting
The Accumax Electromagnetic Meters come with PTFE/PFA lining, which provides exceptional durability and resistance to corrosion, maximizing the meter's lifespan.
Unaffected by Anything
The flow meter’s measurement accuracy is unaffected by variations in the temperature, pressure, density, or viscosity of the fluid.
Broad Range
With a measuring range of 0.2 m3 /h to 1300 m3 /h, this device is suitable for a wide range of applications.
Bidirectional
With our Accumax Electromagnetic Meters measurements that can be made in both directions—forward and backward.
Custom Design
We offer customization in 10 different categories to meet your unique needs and requirement ensuring the perfect fit for your application.
Empty Pipe Alert
Our meters comes with the feature to provide alerts when there is lack of water flow or an unusually low flow rate to avoid downtime and other issues.
Precision & Power Supply
Meters provide high precision measurement often within 0.5% of the reading & come with Universal Power Supply of 85 V AC-270 V AC, 50 Hz60 Hz/ 24 V DC.
Application
Accumax Electromagnetic Flow-meters are used to measure various types of liquids which can be found in various industrial processes like as Acidic chemical, Corrosive Liquids, waste water, warm/hot water.
- ETP (Effluent Treatment Plants)
- STP (Sewage Treatment Plants)
- Chemical Industries
- Food & Sugar Industries
- Pharmaceutical Industries
- Textile Industries
- Ceramic Industries
- Pulp & Paper Mills
- Industrial R.O
- Water supply schemes
Principal of Operation
The Accumax Electromagnetic Flow-meter work on Farady’s Law of Electromagnetic Induction. Hence, the meter detects flow based on velocity of conductive liquid. Thus the meters are Calibrated in terms of volumetric flow rate from it.
Dimensions
Note: Responsibility for the choice of lining and electrode materials as regards abrasion and corrosion resistance lies with the purchaser; the effect of any change in process medium during the operating of the meter should be taken into account. Incorrect selection of lining and/or electrode could lead to a failure of the meter.
Installation Requirements
- Orientation: The flowmeter can be put in any direction, although for optimal results, horizontal installation is advised. U-bend is ideal for these flowmeters. Refer to the installation manual for details.
- Pipe Conditions: For precise measurements, make sure the pipe is continually filled with liquid
Upkeep and calibration
- Maintenance: Because there aren’t any moving parts, little maintenance is needed. The only maintenance typically required is cleaning the electrodes and sensor. However, it is advised to perform regular checkups on the electronic components.
- Calibration: Regular calibration guarantees the best results. To find out the recommended calibration intervals, contact the manufacturer.
Measurement Principle | Electromagnetic |
---|---|
Line Size Options | 15 NB To 350 NB |
Types Available | Integral/ Remote (Up to 10 m Cable Length) |
Flow Measuring Range | 0.2 m³/h to 1300 m³/h |
Measured Variables | Volume flow, mass flow |
Accuracy (or Max. Measurement error) | 0.5% of S. (or +0.5%) |
Repeatability | 0.10% |
Protection Class | IP66/ IP67/ IP68 |
Liner | PTFE (Teflon), Rubber (Neoprene) |
Process Connection | Flange End |
Flow Tube | SS304/SS316 |
Electrode Material | SS316L/ Hastelloy C22 |
Media | Conductive Liquid |
Flow Direction | Forward & Reverse (Reverse flow indicated with (-) sign before flow rate) |
Electrical Conductivity of Liquid | >5 uS/cm >20 uS/cm for water |
Process Pressure | 20 bar or 20 kg/cm2 |
Operating Temperature Range (Medium Temp Range) | -10 (0) °C to +100 °C -10 (0) °C to +200 °C (Remote display) PTFE: up to 230 °C Rubber: up to 85 °C |
Relative Humidity | 0-95% |
Sensor Housing Material | Carbon Steel with protective Varnish |
Calibration Range | Wet calibrated at IEC/ISO/EN17025 accredited calibration laboratory |
Display | Standard 16*2 LCD |
Display Resolution/ Smallest Division | Flowrate: 0.01 L/min or 0.01 m³/h, Totalizer: 10 digits Totalizer |
Transmitter Unit | |
Power Supply | 85 V AC-270 V AC, 50 Hz-60 Hz/ 24 V DC |
Output | 4-20 mA/ RS485/ Pulse |
Power Consumption | <10 VA |
Alarm Output | Low & High Flow Alarm (Open Drain) |
Transmitter Housing Material | AISi10Mg, coated |
Configuration functions/parameters | |
Configuration Data | 3 Tactile Membrane Keys for Data Configuration |
Flow Totalizer Reset | Totalizer Reset Facility by Password Protection |
Units of Measurement | L, m³, kg, kL (User Configurable) |
Damping Time | User Configurable |
Security | Password Protection for Configuration of Data |
Special Function (As Optional Accessories) | |
Batching Facility | Available |
Data Logging | Available |
Telemetry | Available |
Meteorological Approvals and Certificates | Calibration performed on accredited calibration facilities (acc. To ISO/IEC 17025) |
Other Approvals | CE, ISO 4064:2014 |
Warranty | 1 Year |
EFM With Telemeter | |
Compatible with GPRS /GPS | Yes |
Dashboard | Compatible on PC/ Mobile Phone/ iPad |
Reports | Real-Time Data Access |
Multi-User Login | Yes |
Group Allocation | Yes |
Alerts | Temper Alert and Power Failure Alert |
Subscription | Yearly via Payment Gateways |
Reach us out